Goodrive10 Series Mini VFD
Function parameters
-67-
Function
code
Name
Description
Default Modify
speed 6 multi-step terminals 1
–4, and correspond to
multi-step speed 0 to multi-step speed 15.
Output frequency
Terminal 1
Terminal 2
Terminal 3
Terminal 4
When terminal1= terminal 2= terminal 3=
terminal 4=OFF, the frequency input manner is
selected via code P00.06 or P00.07. When not
all terminals are off, it runs at multi-step which
takes precedence of keypad, analog value,
communication frequency input. Select at most
16 steps speed via the combination code of
terminals 1, 2, 3, and 4.
The start-up and stopping of multi-step running
is determined by function code P00.06, the
relationship between terminals 1, 2, 3, and 4 and
multi-step speed is as following:
Termin
al 1
OFF ON OFF ON
OF
F
ON
OF
F
ON
Termin
al 2
OFF OFF ON ON
OF
F
OF
F
ON ON
Termin
al 3
OFF OFF OFF
OF
F
ON ON ON ON
Termin
al 4
OFF OFF OFF
OF
F
OF
F
OF
F
OF
F
OF
F
Step
0
1
2
3
4
5
6
7
Termin
al 1
OFF ON OFF ON
OF
F
ON
OF
F
ON
P10.16
Multi-step
speed 7
0.0%
○
P10.18
Multi-step
speed 8
0.0%
○
P10.20
Multi-step
speed 9
0.0%
○
P10.22
Multi-step
speed 10
0.0%
○
P10.24
Multi-step
speed 11
0.0%
○
P10.26
Multi-step
speed 12
0.0%
○
P10.28
Multi-step
speed 13
0.0%
○
P10.30
Multi-step
speed 14
0.0%
○
P10.32
Multi-step
speed 15
0.0%
○
Summary of Contents for GD10-0R2G-2-B