The output frequency changes as the
this set value, will stop for the fault and
set running time. When the
Function Parameters
76
Function
code
Name
Description
Default
value
Modify
E08.20
Correcting
analog input
and output
0: Correct
1: Not correct
Setting range: 0
–1
0
◎
E08.25
Setting
counting value
The counter counts the input pulse signals through
the S terminals (with the counter triggering
function) or HDI (E05.00=1).
When the counter achieves a fixed number, the
multi-function output terminals will output the
signal of "fixed counting number arrival" and the
counter go on working; when the counter achieves
a setting number, the multi-function output
terminals will output the signal of "setting counting
number arrival", the counter will clear all numbers
and stop to recount before the next pulse.
The setting counting value
should be no
more than the setting counting value
The function is illustrated as below:
S terminal/HDI
HDO, RO1, RO2
HDO, RO1, RO2
Output when
"Setting counting
value" reached
Output when
"Reference counting
value" reached
–65535
: 0
0
○
E08.26
Reference
counting value
0
○
E08.27
Set running
time
Pre-
accumulative running time achieves the set time,
the multi-function digital output terminals will
output the signal of "running time arrival".
Setting range: 0
–65535 min
0m
○
E08.28
Fault reset
times
The time of the fault reset: set the fault reset time
by selecting this function. If the reset time exceeds
wait to be repaired.
The interval time of the fault reset: The interval
between the time when the fault occurs and the
time when the reset action occurs.
: 0
–10
: 0.1
–3600.0s
0
○
E08.29
Interval time of
automatic fault
reset
1.0s
○
E08.30
Frequency
decreasing
load. And it is mainly used to balance the power
0.00Hz
○