Function Parameters
87
Function
code
Name
Description
Default
value
Modify
E10.20
Multi-step
speed 9
communication frequency input. Select at most 16
steps speed via the combination code of terminal
1,terminal 2, terminal 3, and terminal 4.
The start and stopping of multi-step running is
determined by function code
, the
relationship between
terminal 1 (16), terminal 2 (17), terminal 3 (18),
terminal 4 (19) and multi-step speed is as
following:
Terminal 1 OFF ON OFF ON OFF ON OFF ON
Terminal 2 OFF OFF ON ON OFF OFF ON ON
Terminal 3 OFF OFF OFF OFF ON ON ON ON
Terminal 4 OFF OFF OFF OFF OFF OFF OFF OFF
Step
0
1
2
3
4
5
6
7
Terminal 1 OFF ON OFF ON OFF ON OFF ON
Terminal 2 OFF OFF ON ON OFF OFF ON ON
Terminal 3 OFF OFF OFF OFF ON ON ON ON
Terminal 4 ON ON ON ON ON ON ON ON
Step
8
9
10
11
12
13
14
15
Setting range of P10.(2n,1<n<17): -100.0
–100.0%
Setting range of P10.(2n+1,1<n<17):
0.0
–6553.5s(min)
0.0%
○
E10.21
Running time of
step 9
0.0s
○
E10.22
Multi-step
speed 10
0.0%
○
E10.23
Running time of
step 10
0.0s
○
E10.24
Multi-step
speed 11
0.0%
○
E10.25
Running time of
step 11
0.0s
○
E10.26
Multi-step
speed 12
0.0%
○
E10.27
Running time of
step 12
0.0s
○
E10.28
Multi-step
speed 13
0.0%
○
E10.29
Running time of
step 13
0.0s
○
E10.30
Multi-step
speed 14
0.0%
○
E10.31
Running time of
step 14
0.0s
○
E10.32
Multi-step
speed 15
0.0%
○
E10.33
Running time of
step 15
0.0s
○
E10.34
Simple PLC
0
–7 step
ACC/DEC time
Below is the detailed instruction:
Function
code
Binary bit
Step
ACC/DEC
0
ACC/DEC
1
ACC/DEC
2
ACC/DEC
3
BIT1
BIT0 0
00
01
10
11
BIT3
BIT2 1
00
01
10
11
BIT5
BIT4 2
00
01
10
11
BIT7
BIT6 3
00
01
10
11
BIT9
BIT8 4
00
01
10
11
BIT11 BIT10 5
00
01
10
11
BIT13 BIT12 6
00
01
10
11
BIT15 BIT14 7
00
01
10
11
BIT1
BIT0 8
00
01
10
11
BIT3
BIT2 9
00
01
10
11
0x0000
○
E10.35
Simple PLC
8
–15 step
ACC/DEC time
0x0000
○