18
Optidrive P2 Elevator User Guide V2.30
Electrical Installation
www.InvertekDrives.com
Control Terminal Wiring
1.
All analog signal cables should be suitably shielded. Twisted pair cables are recommended.
2.
Power and Control Signal cables should be routed separately where possible, and must not be routed parallel to each other
3.
Signal levels of different voltages e.g. 24 Volt DC and 110 Volt AC, should not be routed in the same cable.
4.
Maximum control terminal tightening torque is 0.5Nm
Control Terminals Connection Diagram
Control Terminal Designations and Default Function Assignments
+24Vdc 100mA Output
+10Vdc 10mA Output
Open = Terminal 4 Selection
Closed = Inspection Speed
0V
Drive Healthy (24Vdc Output)
0V
Open = Terminal 4 Selected Speed
Closed = Intermediate speed
Drive Running (24Vdc Output)
ST0 +
ST0 -
RL1-C
RL1-NO
RL1-NC
RL2-A
RL2-B
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
+24Vdc
0Vdc
Optional
External
Power
Supply
Open = Levelling Speed
Closed = Run Speed
Motor Contactor
Control
Common
Motor Brake
Control
Common
Open = StoP
Closed = Run Up (Forward)
Open = StoP
Closed = Run Down (Reverse)
For SAFE TORQUE OFF Input (STO+/STO-) Also refer to section 7.1.8
Logic High = 18-30Vdc (“SAFE TORQUE OFF” Standby mode.).
Control Terminal Connections
Main Terminal Strip
1
+24V
+ 24V User Input / Output
100mA User Output
2
DI 1
Input 1
Digital 8 – 30 Volt DC
3
DI 2
Input 2
Digital 8 – 30 Volt DC
4
DI 3
Input 3
Digital 8 – 30 Volt DC
5
+10V
+ 10 Volt User Output
10mA for user potentiometer
6
DI 4
Input 4
Digital 8 to 30V DC
7
0V
0 Volt Common
8
AO1
Output 1
1
st
Analog / Digital Output, 0 to 10V, 4 to 20mA or +24VDC Digital
9
0V
0 Volt Common
10
DI 5
Input 5
Digital 8 to 30V DC
11
AO2
Output 2
2
nd
Analog / Digital Output, 0 to 10V, 4 to 20mA, Digital 24V
12
STO+
Drive hardware inhibit
“Safe torque Off” 24V input - must be linked to ext +24 Volt (18 – 30 Volt) DC to enable
power stage
13
STO-
Inhibit 0V input
0V return for the 24V “Safe torque OFF” input (STO)
Additional Terminal Strip
14
RL1-C
Relay Output 1 Common
Relay contacts, 250V AC, 30V DC, 5A
15
RL1-NO
Relay Output 1 NO
Relay contacts, 250V AC, 30V DC, 5A
16
RL1-NC
Relay Output 1 NC
Relay contacts, 250V AC, 30V DC, 5A
17
RL2-A
Relay Output 2 Common
Relay contacts, 250V AC, 30V DC, 5A
18
RL2-B
Relay Output 2 NO
Relay contacts, 250V AC, 30V DC, 5A