iV-Light ventilation unit | Installation instructions
4.8 Check function and complete fan installation
►
Set unidirectional ventilation operating mode (DL) on the connected controller.
(see the controller's installation and operating instructions)
►
Make sure that all reversible fans rotate in the direction appropriate to their connections.
Start direction extract air mode:
Start direction supply air mode:
• The clamping screws of the plug connection are directed to the same side.
• The connections of the white and brown cable are swapped.
1 Fan cable [to the fan]
2 Plug-in connector on the fan cable
3 Plug-in connector on the controller cable
4 Fan BUS [to controller]
5 Clamping screws on the controller plug-in
connector
6 Clamping screws on the fan plug-in
connector
Plug-in connector
on the fan cable
Plug-in connector (cable coming from controller)
Start direction extract air
Start direction supply air
Terminal
block
Colour
Terminal
block
Meaning
Colour Terminal
block
Meaning
Colour
CW (–)
Blue
III (–)
GND (–)
White
V (–)
GND (–)
Brown
+
Red
IV (+)
Operating
voltage
Green
IV (+)
Operating
voltage
Green
CCW (–)
Black
V (–)
GND (–)
Brown
III (–)
GND (–)
White
The functional test has been performed.
►
Set heat recovery operating mode (WRG) on the connected controller.
(see the controller's installation and operating instructions)
►
Push the connected and checked fan as far as the thermal accumulator.
inVENTron is connected and installed.
IV (+)
(+)
V (–)
III (–)
III (–)
V (–)
IV (+)
CW (–)
CCW (–)
(+)
CW (–)
CCW (–)
6
3
2
5
1
1
2
3
6
5
4
4
Summary of Contents for 1001-0200
Page 1: ...www inventer de Installation instructions iV Light ...
Page 37: ...37 WARRANTY AND GUARANTEE 37 iV Light ventilation unit Installation instructions NOTES ...
Page 38: ...38 WARRANTY AND GUARANTEE 38 iV Light ventilation unit Installation instructions NOTES ...
Page 39: ...39 WARRANTY AND GUARANTEE 39 iV Light ventilation unit Installation instructions NOTES ...