SERVICE MANUAL
Invacare
®
- STORM
4
MAX
18
4.2.1
ACS 2 PMA90L electronics module
Connections
1) Battery 24V
2) Cable to G-Trac module (GYRO
3) Bus cable (to remote or ACT)
4) Motor M1
5) Light
6) Motor M2
Rubber stoppers for free slots
2) & 3) Order number: 1552876
4.2.2
ACT actuator module
A range of adjusting motors, also known as actuators, can be fitted to the mobility aid. These
actuators are either connected directly to the power module or to a separate actuator module. The
actuator module is connected to the power module via a bus cable.
4.2.2.1
ACT 2 actuator module
Connections
1) ACI*
2) Bus cable (to remote or ACT)
3) Bus cable (to remote or ACT)
4) Adjusting motor/actuator - Channel 2
5) Adjusting motor/actuator - Channel 1
Rubber stoppers for free slots
1) Order number: 1555701
2) & 3) Order number: 1552876
4) & 5) Order number: 1555700
* The ACI connection is used for actuator limitation or speed reduction.