background image

ITABAR Flow Sensor Type 

FTMD 

Operating manual

 

 

8

6
10

3
4

7

5

 

Fig. 11 Sensor profile with protection pipe 

 

6.2 Installation of Type FTMD-26 

The design of the ITABAR Sensor of the type 
FTMD-26 is almost identical to the type FTMD-25. 
The only difference is the sensor end support (with 
sealing plug, see Fig. 12) which permits higher 
stream velocities in the pipe. 
 
 

Attention! 

Due to construction of the FTMD-26 with end 
support it would cause many problems to install it 
for the first time during operation. 
We recommend you to install this type during 
operation stop as per following instructions. 
After installation also this sensor can rejected and 
inserted as type FTMD-25 under pressure. 

 

Installation of weld socket: 

1.  Drill a hole of 35 mm diameter into the pipe. 

2.  Tack the weld socket {1} onto the pipe leaving 

approx. 2 mm clearance. Align the socket (e.g. 
with a bolt or pin) so that it is exactly perpen-
dicular to the pipe axis (Fig. 12). 

3.  Before final welding and installing the sensor, 

you have to mount the end support {5}. 

 
 

Installation of the end support: 

4.  Take a cord and tie one end around the installed 

weld socket {4}. Wrap the other end of the cord 
around the pipe so that it forms a loop around 
the pipe. Mark the half-way point of the pipe 
circumference on the pipe. 

5.  Now drill a second hole of 

35 mm diameter 

into the pipe. 

6.  Remove the sealing plug {9} (if present) from 

the sensor end support. Tack the sensor end 
support onto the pipe leaving approximately 2 
mm clearance. (Fig. 12) 

7.  Insert the sensor into the pipe and check the 

alignment of the sensor end support. If 
necessary, correct the alignment. 

 

2

1

5

9

 

Fig. 12: Installation hardware and sensor end 

support 

 
8. Now the final welding can be carried out. 

Check the alignment of the weld socket again! 
For permissible deviations, see chapter 5.4. . 

9.  For sensor end supports with sealing plug only: 

Seal the thread of the sealing plug {9} with a 
suitable sealing compound (e.g. PTFE tape). 
Screw the sealing plug into the sensor end 
support and tighten it firmly (Fig. 12). 

10. Install the Flo-Tap unit isolating valve {2} on 

the welding socket. Verify that the valve is in 
fully open position, and that the stem is in line 
with the pipe to insure clearance for the insert-
retract rods. 

11. Perform the installation of the sensor into the 

pipe according to the instructions given in 
chapter 6.1 steps 10 through 15. 

Summary of Contents for Analog Node

Page 1: ...Installation of the ITABAR Sensor 6 6 1 Installation of Type FTMD25 6 6 2 Installation of Type FTMD26 7 6 3 Insertion Procedure for FTMD 8 6 4 Retract Procedure for FTMD 8 7 Installation of the Attach...

Page 2: ...ept for drilling and welding equipment These instructions call for the use of a Mueller DH 5 drilling machine or equivalent which is rated for 80 bar at 35 C with a maximum temp erature of 120 C This...

Page 3: ...1 Determination of Pipe Arrangement For design reasons the pipe arrangement at the installation location has to be known before the sensor is manufactured For horizontal pipe arrangements the instrume...

Page 4: ...flow measurements in a horizontal pipe the ITABAR Sensor must be installed in the lower half of the pipe circumference the connections to the instruments have to be located below the pipe axis Fig 5...

Page 5: ...eous installation location As a general rule regulating valves throttle valves and gate type valves should be installed behind the sensor Note If the recommended straight pipe run lengths are not avai...

Page 6: ...l flanged nipple 8 Drill through the pipe wall in accordance with the instructions supplied with the drilling machine For type FTMD 25 35mm 9 Withdraw the drill past the Flo Tap unit isolating valve C...

Page 7: ...one end around the installed weld socket 4 Wrap the other end of the cord around the pipe so that it forms a loop around the pipe Mark the half way point of the pipe circumference on the pipe 5 Now dr...

Page 8: ...h temperature gland additional adjustment may be required at this time 8 6 10 3 4 Fig 13 retracted Flo Tap Sensor 5 Connect instrument lines to the instrument valves and to the appropriate meter recor...

Page 9: ...followed by a zero point error We recommend you to install the differential pressure lines close together connect hi and lo line heat conducting to maintain equal temperature Attention The differenti...

Page 10: ...ng signal The ITABAR sensors are head measuring devices and will not accurately measure two phase flow ITABAR Flow Sensors for low pressure steam have condensate pots in which the condensate water lin...