background image

ITABAR Flow Sensor Type 

FTMD 

Operating manual

 

 

6. Installation of the ITABAR Sensor 

Observe the general installation notes!

 

 

6.1 Installation of Type FTM-20 and FTM-25 

1.  Verify that the line pressure is with rated limits 

of the drilling equipment to be used. 

2.  Grind off paint or other coatings from the pipe 

in the area where the Flo-Tap is to be installed. 

3.  Tack the mounting stud {1} (supplied with the 

Flo-Tap) onto the pipe leaving a clearance of 1-
2 mm (Fig. 9). 

4. Check the alignment of the mounting stud 

again. Then the finish weld can be made. 

5.  Fasten unit isolating valve {2} to the mounting 

stud {1} and open valve. (Fig. 9). 

 

2

1

Fig. 9:  Mounting stud with isolating valve 
 
6. Fasten special adapter flanged nipple to unit 

isolating valve (Fig. 10). 

7.  Install cutter arbor, shell cutter and pilot drill to 

pressure drilling machine and attach the 
machine to its special flanged nipple. 

8.  Drill through the pipe wall in accordance with 

the instructions supplied with the drilling 
machine. For type  FTMD-25 

 35mm. 

9. Withdraw the drill past the Flo-Tap unit 

isolating valve. Close the unit valve and remove 
drilling machine and special flanged nipple. 
Check for leakage at valve and connections. 

10. Verify that the sensor profile {4} is fully 

retracted in the protection pipe {3}. Check the 
position of the threaded rod (Fig. 11) 

 
 

 
Fig. 10:  Drilling machine with adapter nipple 

mounted on unit isolating valve 

 
 
11. Now  seal the threaded stud {5} with a suitable 

sealing compound (Fig. 11). 

12. Install the threaded stud {5} on the isolating 

valve {2} (Fig. 9 and 11). 

13. Verify that the instrument valves are fully 

closed. 

14. Check all connections for leakage by cracking 

open the unit isolating valve. If necessary, 
screw down the 4 screws {6} of the top packing 
gland and the 4 screw nuts {7} of the bottom 
packing gland  (Fig. 11). 

15. Increase line pressure to normal limits and 

check for leakage. If there is no apparent 
leakage, proceed to Flo-Tap Insertion 6.3.  

Summary of Contents for Analog Node

Page 1: ...Installation of the ITABAR Sensor 6 6 1 Installation of Type FTMD25 6 6 2 Installation of Type FTMD26 7 6 3 Insertion Procedure for FTMD 8 6 4 Retract Procedure for FTMD 8 7 Installation of the Attach...

Page 2: ...ept for drilling and welding equipment These instructions call for the use of a Mueller DH 5 drilling machine or equivalent which is rated for 80 bar at 35 C with a maximum temp erature of 120 C This...

Page 3: ...1 Determination of Pipe Arrangement For design reasons the pipe arrangement at the installation location has to be known before the sensor is manufactured For horizontal pipe arrangements the instrume...

Page 4: ...flow measurements in a horizontal pipe the ITABAR Sensor must be installed in the lower half of the pipe circumference the connections to the instruments have to be located below the pipe axis Fig 5...

Page 5: ...eous installation location As a general rule regulating valves throttle valves and gate type valves should be installed behind the sensor Note If the recommended straight pipe run lengths are not avai...

Page 6: ...l flanged nipple 8 Drill through the pipe wall in accordance with the instructions supplied with the drilling machine For type FTMD 25 35mm 9 Withdraw the drill past the Flo Tap unit isolating valve C...

Page 7: ...one end around the installed weld socket 4 Wrap the other end of the cord around the pipe so that it forms a loop around the pipe Mark the half way point of the pipe circumference on the pipe 5 Now dr...

Page 8: ...h temperature gland additional adjustment may be required at this time 8 6 10 3 4 Fig 13 retracted Flo Tap Sensor 5 Connect instrument lines to the instrument valves and to the appropriate meter recor...

Page 9: ...followed by a zero point error We recommend you to install the differential pressure lines close together connect hi and lo line heat conducting to maintain equal temperature Attention The differenti...

Page 10: ...ng signal The ITABAR sensors are head measuring devices and will not accurately measure two phase flow ITABAR Flow Sensors for low pressure steam have condensate pots in which the condensate water lin...

Reviews: