background image

ITABAR Flow Sensor Type 

FTMD 

Operating manual

 

 

5.5 

Required Undisturbed Pipe Run Lengths 

 

(in multiples of D) 

The accuracy of the measurements of the ITABAR 
Sensor depends on the development of a stream 
profile which should be as undisturbed as possible. 
Therefore the selection of the installation location 
within the pipe run is of considerable importance. 
The following tried and true hints regarding the 
required pipe lengths ahead of and behind the 
sensor are designed to help you in your selection of 
the most advantageous installation location. 
As a general rule, regulating valves, throttle valves 
and gate-type valves should be installed behind the 
sensor. 

 
 
 

 

Note: 

If the recommended straight pipe run lengths are 
not available, the measuring accuracy can be 
adjusted to the specific conditions of the measuring 
stretch by conducting a comparison measurement 
(e.g. Pitot tube, point measurement). 
The point measurement guarantees that the 
differential pressure corresponds to the true flow 
velocity, thereby assuring the specified accuracy. 
Details can be requested from the manufacturer. 

D = Pipe Diameter 

A = U p s t r e a m   B = D o w n s t r e a m

 

7

 

 

3

 

 

9

 

 

3

 

 

17

 

 

4

 

 

18

 

 

4

 

  R e s t r i c t i o n   i n   t h e   P i p e   R u n  

 

7

 

 

3

 

  W i d e n i n g   o f   t h e   P i p e   R u n  

 

7

 

 

3

 

    R e g u l a t i o n   D e v i c e  

 

24

 

 

4

 

Summary of Contents for Analog Node

Page 1: ...Installation of the ITABAR Sensor 6 6 1 Installation of Type FTMD25 6 6 2 Installation of Type FTMD26 7 6 3 Insertion Procedure for FTMD 8 6 4 Retract Procedure for FTMD 8 7 Installation of the Attach...

Page 2: ...ept for drilling and welding equipment These instructions call for the use of a Mueller DH 5 drilling machine or equivalent which is rated for 80 bar at 35 C with a maximum temp erature of 120 C This...

Page 3: ...1 Determination of Pipe Arrangement For design reasons the pipe arrangement at the installation location has to be known before the sensor is manufactured For horizontal pipe arrangements the instrume...

Page 4: ...flow measurements in a horizontal pipe the ITABAR Sensor must be installed in the lower half of the pipe circumference the connections to the instruments have to be located below the pipe axis Fig 5...

Page 5: ...eous installation location As a general rule regulating valves throttle valves and gate type valves should be installed behind the sensor Note If the recommended straight pipe run lengths are not avai...

Page 6: ...l flanged nipple 8 Drill through the pipe wall in accordance with the instructions supplied with the drilling machine For type FTMD 25 35mm 9 Withdraw the drill past the Flo Tap unit isolating valve C...

Page 7: ...one end around the installed weld socket 4 Wrap the other end of the cord around the pipe so that it forms a loop around the pipe Mark the half way point of the pipe circumference on the pipe 5 Now dr...

Page 8: ...h temperature gland additional adjustment may be required at this time 8 6 10 3 4 Fig 13 retracted Flo Tap Sensor 5 Connect instrument lines to the instrument valves and to the appropriate meter recor...

Page 9: ...followed by a zero point error We recommend you to install the differential pressure lines close together connect hi and lo line heat conducting to maintain equal temperature Attention The differenti...

Page 10: ...ng signal The ITABAR sensors are head measuring devices and will not accurately measure two phase flow ITABAR Flow Sensors for low pressure steam have condensate pots in which the condensate water lin...

Reviews: