Initial startup and operation
Checks before the initial startup
4
Ensure that the base plate of the Pallet Control is correctly fastened to the profile.
4
Ensure that the Pallet Control is correctly fastened to the base plate.
4
Ensure that all screws are properly tightened.
4
Ensure that no additional danger zones have been created due to interfaces to other
components.
4
Ensure that the wiring is in accordance with the specification and legal requirements.
4
Check all protective devices.
4
Ensure that there are no persons in the danger zones of the conveyor system.
NOTICE
Observe Pallet Drive connection diagrams
Damage to the Pallet Drive or Pallet Control is possible if connections are incorrect.
4
Ensure that the holding brake and thermal circuit breaker connections are correct.
4
Ensure that the status LEDs are on after the power supply has been switched on.
Start
After a cold start, the Pallet Control requires less than 2 seconds to initialize. During this process
the system also checks whether or not holding brakes are connected.
After each restart, the Pallet Control waits for a travel signal from one of the two inputs of each
motor.
Avoid frequent changes of direction. At more than 4 changes of direction per minute, the service
life of the center zero relay is greatly reduced.