Interroll Pallet Control PC 6000
Version 2 (02/2020) en
Translation of original operating instructions
17
Assembly and installation
Warning notices for installation
NOTICE
Risk of property damage that may cause failure or shortened service life
4
Check each Pallet Control for visible damage before installation.
4
Ensure that the Pallet Control is not warped during installation (no bending or torsion).
4
Do not drill additional mounting holes into the housing or enlarge the holes provided.
4
Do not drop the Pallet Control to prevent internal damage.
4
Install the Pallet Control only in a horizontal position on the conveyor frame in such a way
that the labeling can be read. Other variants are not allowed and require the approval of
Interroll.
NOTICE
Protection class IP54 is ensured only with proper installation.
4
Close the housing correctly. The tightening torque of the housing screw is 2.8 Nm.
4
Firmly tighten cable connections or, if not used, apply dummy caps.
4
Close USB cover.
Installation
The rear plate features three holes for M5 screws for fastening the Pallet Control to the
conveyor frame. The PC 6000 is intended for installation on a metal frame.
If possible, install all Pallet Controls only on one side of the conveyor system to simplify the
electrical installation.
4
Identify a flat area on the conveyor frame where the Pallet Control can be installed. Do not
use any spacer bushings.
4
Ensure that there is sufficient space for the cable entry on the left and right.
4
Hold the Pallet Control to the conveyor frame and mark the center of the installation holes.
Observe the correct orientation of the housing.
4
Drill three holes with ø 5.5 mm at the markings in the conveyor frame.
4
Screw the baseplate onto the conveyor using M5 screws.
4
Ensure that the rear plate is not twisted.