Interroll Pallet Control PC 6000
Assembly and installation
Version 2 (02/2020) en
Translation of original operating instructions
21
X1 and X2: Outputs for
400 V line voltage and
motors
The circuit board features one 12-pin circuit board terminal of type WAGO 739 on each side,
left and right. Cores up to 2.5 mm² can be connected here. If wire end sleeves are used, the
cross section is limited to 1.5 mm². The M20 (3 A) or M25 (10 A) cable connectors on the left
and right side of the housing are intended for connecting or looping through the 400 V supply.
The permissible line diameter is 6 – 13 mm (3 A) or 8 – 17 mm (10 A).
The M16 (3 A) or M10 (10 A) cable connectors on the left and right side of the housing are
intended for connecting the drives. The permissible line diameter is 4 – 10 mm (3 A) or
6 – 13 mm (10 A).
The terminal designations are printed on the circuit board.
X1
X3
X4
X5
X2
Designation
Function
Direction
BR-
Holding brake 1 GND
Output
BR+
Holding brake 1 +24 V
Output
T1
Thermal circuit breaker 1 input Input
T2
Thermal circuit breaker 1 +24 V Output
PE
PE
Grounding
U
Motor1-U
Output
V
Motor1-V
Output
W
Motor1-W
Output
L1
L1 400 V
Input/output
L2
L2 400 V
Input/output
L3
L3 400 V
Input/output
PE
PE
Grounding
X1 and X2: Assignment from top to bottom
The thermal circuit breaker input is intended for use with bimetallic elements (Klixon).