The Pallet Control is equipped with three replaceable miniature fuses of type 5 x 20; 3.15 A
time-lag or 10 A medium time-lag that are used for device protection (1). Protection of the
supply cables must be ensured by the operator,
see "Warning notices concerning the electrical
1
X1
X2
X3
X4
Replacing fuses
DANGER
Danger to life – electrocution
4
Fuses may be replaced only by an electrician!
4
Observe the safety information.
4
Loosen the hexagon socket screw (3) located in the center to open the housing. An Allen key
size 4 is required.
4
Remove the fuses using a suitable tool.
4
Insert the fuses using a suitable tool.
4
Replace the housing and tighten it again. The tightening torque of the screw is 2.8 Nm.