4.6 Programming
Commands
If you need to change any of the program default
values or wish to add functions, first enter Program
mode and then enter the desired program command.
Defaults are in bold.
Action Desired
Press
Details
To enter Program
mode
99 # (Master Code)
*
Yellow LED blinks
slowly (default
Master Code
= 1234)
1. Change Master
Code
Code-only
operation
(example, 4321
Master Code)
1 # (new code) * (repeat code) *
1 # 4321 * 4321 *
2. Assign outputs
10 # virtual output # physical output #
**
Virtual Output
Physical Output
1 - Lock
1 - Relay 1 (Main)
2 - Alarm Shunt
2 - Relay 2 (Aux)
3 - Propped Door
5 - Audio Alert #1
4 - Forced Door
6 - Audio Alert #2
Entering a zero (0)
for a virtual output
disables the
physical output
3. Set lock output
duration
11 # tt # 0 # * *
tt = number of
seconds to operate
lock on access (1
through 255)
defaults to 5
seconds
4. Delete users
user-location # **
Chapter 4: Programming
4.6 Programming Commands
4-34
prox.pad plus Install/Program. Manual, PPP, D2