
4.2.5 Batch Load
Cards Manually
(without presentation)
“Batch entry” allows you to enter multiple, sequential
26-bit HID cards into the prox.pad plus unit’s memory
at one time. (Keeping IEI proximity cards in order is
easy as the code is printed on the front of each card.)
NOTE:
The facility code must be programmed into
the unit before any batch entry can occur. The facility
code MUST be programmed only once. The default
facility code is 11. For the programming sequence
used to enter the 3-digit facility code, see command
32, parameter 4 (see table in section 4.6).
To add several users from the proximity reader, follow
this procedure:
1.
Place the prox.pad plus unit in Program mode.
Press:
99 # Master Code *
(default is 1234)
A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk
*
key.
2.
On the prox.pad plus keypad, press:
57 # (total number of cards to be added) #
(starting user location) # card number *
repeat card number *
NOTE:
Never enter one (1) or (2) as the starting user
location since they are reserved for the Master code
and Supervisor code, respectively.
3.
On the prox.pad plus keypad, press
*
to exit Pro-
gram mode.
Up to 1998 users can be added this way at one
time. (User 1 is reserved for the Master code, User
2 for the Supervisor code.)
Chapter 4: Programming
4.2 Programming Users
4-14
prox.pad plus Install/Program. Manual, PPP, D2