Select “Filler or “REX” operation and affix the
appropriate IEI-provided label to the filler piece.
For Filler operation
, no tabs are broken off the
filler piece, which merely sits in place of the re-
motely located antenna, once the main circuit
board and cabling are replaced.
For REX operation
, break off the labeled tabs,
which allows a spring-loaded tab to engage the
REX switch on the main circuit board and open
the door.
•
Replace the main circuit board into the key-
pad/controller and Pin connector P4 to the main
circuit board.
•
Connect the front keypad/controller of the unit to
the back housing.
•
Secure with a hex socket screw using the supplied
hex wrench, or secure with a tamper screw
(optional tool required).
Chapter 2: Installation
2.4 Mounting the prox.pad plus Unit
2-14
prox.pad plus Install/Program. Manual, PPP, D2