3.4 Testing the
prox.pad plus
At this point in a typical installation, it is assumed that
the prox.pad plus unit has been mounted and wired
successfully as described earlier and that testing can
begin.
IEI recommends, however, that first-time in-
stallers test the prox.pad plus unit BEFORE actually
mounting and wiring the unit to become familiar with
its operation.
3.4.1 Testing the
Controller/Keypad
1.
Connect the positive (+) lead of the power supply
to the V+ input on the prox.pad plus control-
ler/keypad.
2.
Connect the negative (-) lead of the power supply
to the V- input on the prox.pad plus control-
ler/keypad.
3.
Turn ON the power supply.
4.
Ensure that the bi-color LED (red and green) on
the prox.pad plus unit lights red.
5.
On the prox.pad plus controller/keypad, press:
7890 # 123456 *
If all 12 key presses are verified, the prox.pad plus
unit enters the self-test mode. The bi-color LED
turns green. The red LED blinks alternately with
the yellow LED and then both turn OFF. Next,
the sounder beeps three times, pauses, and then
beeps once more. If this does not occur, attempt
to enter the self-test mode again by repeating step
5.
NOTE:
If you are using the IEI DCD software, you
can capture the self-test data on a PDA. This data
contains information about the device.
6.
Enter the master code on the keypad by pressing:
1234 *
The red LED turns OFF and the green LED turns
ON for five seconds while the main relay ener-
gizes. To program the unit, see Chapter 4.
Chapter 3: Wiring
3.4 Testing the prox.pad plus
3-16
prox.pad plus Install/Program. Manual, PPP, D2