![Interlogix TruVision TVB-5701 Configuration Manual Download Page 54](http://html1.mh-extra.com/html/interlogix/truvision-tvb-5701/truvision-tvb-5701_configuration-manual_2077161054.webp)
52
TruVision IP Thermal Camera Configuration Manual
c) Select the
Rule 1
check box and select two frame rules from the drop-down lists
to compare the saved regions.
d) Set the alarm rules and the temperature.
For example, for
Rule 1
select
Temperature Difference is Higher than
, and
enter 10 °C (50 F°). An alarm is triggered when the difference between the
minimum and the maximum region temperatures is greater than 10 °C.
Note
: The
Region
Temperature Difference Alarm
only applies to the targets
set by the frames.
e) To compare other pairs of frame rules, click the next rule check box and repeat
the instructions described in steps c and d.
f) Click
OK
to save the changes.
5. Set the alarm linkage.
Click the
Alarm Linkage
button to enter the alarm linkage window and select the
desired linkage methods. The linkage methods selected apply to all region
temperature difference alarms.
Notify Surveillance
Center
Send an exception or alarm signal to remote management software
when an event occurs.
Send Email
Send an email to a specified address when there is an alarm input or
output alarm.
Note
: You must configure email settings before enabling this option.
See “To set up the email parameters” on page 18 for further
information. If you want to send the event snapshot together with the
email, select the
Attached Snapshot
option.