IFS NS3601-24P/4S GE-DSSG-244 and 244-POE User Manual
29
Figure 2-12
Ring Stack topology
Connecting Stacking cable
Before attempting to connect stacking ports, verify that you have the required stack cables. The following cables are used to connect
stacked switches:
•
NS-CBL-50
: 50cm, Short stack cable –used to connect adjacent IFS switches.
•
NS-CBL-200
: 200cm, Long / Redundant stack cable – used to connect the top and bottom IFS switches of a stack.
There are two high-performance HDMI-like Stack ports on the rear panel for proprietary management stack. Only these IFS stacking
cables can be used for proper functionality.
STEP-1:
Plug one end of the cable in the “
STX1 / Cascade Down
” port and the other end to the ”
STX2 / Cascade UP
” port of next
device.
STEP-2:
Repeat the step for every device in the stack cluster, then ending at last switch.
Figure 2-13
Stacking connection
STEP-3
: If you wish to implement stack redundancy, use the long stack cable NS-CBL-200 to connect the stack port marked “
STX1 /
Cascade Down
” on the bottom switch to the port marked “
STX2 / Cascade Up
” on the top switch of the stack.