![background image](http://html.mh-extra.com/html/interlogix/alliance-al-4017/alliance-al-4017_installation-manual_2076746029.webp)
19
Specifications
General specifications
These specifications are for the AL-4017 and AL-4617 main board (no accessories).
AL-4017 external terminals
1. AL-1692
2. AL-1690, AL-1691.
Current consumption PCB
205 mA nominal
End-of-line resistors
Default: 4.7 k ohm (other: 10 kohm, 6.8 kohm, 5.6 kohm, 3.74 kohm, 3.3 kohm, 2.2 kohm, 2 kohm,
1.5 kohm) 5%, 0.25 W
Housing dimensions
21 x 14.5 x 4.5 in. (533 x 368 x 114 mm)
Operating temperature
32 to 120°F (0 to 49°C)
Humidity
85% noncondensing
Listings
UL 294, Standard for Access Control System Units
UL 365, Standard for Police Station Connected Burglar Alarm Units and Systems
UL 609, Standard for Local Burglar Alarm Units and Systems
UL 1610, Standard for Central-Station Burglar-Alarm Units
UL 1635, Standard for Digital Alarm Communicator System Units
Part
Terminal
Description
Min.
Typ
Max
Unit
J17
AC
Input
16.5
1
24
2
2,1
VAC
A
BATT
Battery connection
Battery charge
Battery AH rating
9
17.2
12
14
1
34.4
VDC
A
AH
J14, J10
AUX, POWER
COMMS
Auxiliary power outputs
System bus power output
9
13.8
14
300
VDC
mA
J13
EXT Siren
Alarm outputs
9
13.8
14
VDC
J9
BELL
Dry relay output
30
1
VDC
A
Summary of Contents for Alliance AL-4017