Alliance AL-4017/AL-4617 Control Panel
Installation Manual
12
PSTN connections
Figure 12
shows two methods to wire the control panel to a PSTN connection. This equipment complies with
FCC Part 68 rules (US:GEIAL07B3-4000).We recommend you wire the system to a dedicated PSTN line.
Figure 12. PSTN connections
PSTN
connection
Tip green
Ring red
RJ31X
Premises (tip)
Premises (ring)
RJ45
RJ11
Premises phone
RJ45
Control panel
Chassis ground
BX
AX
B
A
J8
J7
AC
BA
TT
C
O
MM
S
Zone inputs
A to pin 5 on RJ45 cable
B to pin 4 on RJ45 cable
AX to pin 1 on RJ45 cable
BX to pin 8 on RJ45 cable
PSTN
connection
Tip green
Ring red
RJ31X
Premises (tip)
Premises (ring)
RJ45
RJ11/12
Premises phone
RJ45
Pin 1 and 8 - premises phones
Pin 4 - premises (tip)
Pin 5 - premises (ring)