Table 6-3
Temperature area and alarm configuration
Parameter
Description
Setting
Channel
N/A
[Setting method]
Select a value from the
drop-down list box.
[Default value]
1
Measure Mode
Set at temperature parameter
interface.
N/A
PTZ Area(only
use for PTZ
cameras)
Choose or set the preset, adjust
the camera with PTZ keyboard.
The all presets can set 20 areas
to alarm
Set the preset manually,
or select an existing preset
in the drop-down list.
Enable
Tick to enable alarm areas.
N/A
ID
It ranges from 0 to 19.
N/A
Name
Area name of temperature area.
[Setting method]
Enter a value manually.
Type
Type of temperature area.
ID 0 is default rectangle area,
which is full screen.
There are 20 areas can be set,
these are from 0 to 19 area.
[Setting method]
Select a value from the
drop-down list box.
[Default value]
Rectangle/Point
Alarm Type
Threshold alarm and
Temperature difference alarm
are available for alarm type.
[Setting method]
Select a value from the
drop-down list box.
[Default value]
Threshold alarm
Warning Value
Camera will warn when the
surveillance object temperature
reaches the warning value.
[Setting method]
Enter a value manually.
[Default value]
48.00
Alarm Value
Camera will alarm when the
surveillance object temperature
reaches the alarm value.
[Setting method]
Enter a value manually.
[Default value]
50.00
Maximum Alarm
Value
The maximum value of the
alarm range, if the alarm value
is exceeded, no alarm will be
generated.
[Setting method]
Enter a value manually.
[Default value]
60.00