Servicing the Server Boards
220
Intel® Server Platforms SR6850HW4 and SR6850HW4/M Product Guide
Installing the Front Panel I/O Board
1.
Observe the safety precautions, warnings, and cautions described in “
2.
Set the front panel I/O board in place over the hooks. See letters “A” and “B” in Figure 123.
3.
Slide the front panel I/O board forward until seated over the hooks. See letter “C” in the figure.
4.
Engage the tab on the chassis into the slot on the board. Slide the front panel I/O board forward
until seated.
5.
Tighten the captive screw. See letter “D” in the figure.
6.
Reconnect all cables you disconnected when you removed the front panel I/O board. For
connection locations, see Figure 87.
7.
Install the processor air baffle. For instructions, see “
Installing the Processor Air Baffle
”, page
8.
Re-install the top cover. For instructions, see “
TP01444
A
C
B
B
C
D
Figure 123. Installing the Front Panel I/O Board