![Intel SR6850HW4 - Server Platform - 0 MB RAM Product Manual Download Page 199](http://html1.mh-extra.com/html/intel/sr6850hw4-server-platform-0-mb-ram/sr6850hw4-server-platform-0-mb-ram_product-manual_2072153199.webp)
199
TP01562
B
A
Figure 105. Removing External SCSI Filler Panel
11.
Install the external of the cable into the rear panel cutout using the attached tool-less bracket
feature located on the end of the cable assembly.
12.
Install the memory boards or memory board air baffles into Slots C and D. For instructions, see
“
Cold Insertion of a Memory Board
”, page 165.
13.
Install the Fibre Channel Module if you removed it earlier. For instructions, see “
14.
Reinstall any other boards or baffles removed. Make sure the cable is not pinched between the
assemblies.
15.
Re-install the top cover. For instructions, see “
Replacing Removable Media Devices
The Intel
®
Server Platform SR6850HW4 accommodates a DVD-ROM/CD-ROM device and two
5¼-inch peripheral devices. The devices are not hot-swappable, so the system must be powered
down and the AC power cords removed from the chassis before the devices can be serviced. The
DVD-ROM/CD-ROM drive is housed in a sheetmetal carrier. It also has a SATA-to-IDE converter
board. The 5 ¼ inch devices have slide rails that mount into the chassis.
Removing the CD-ROM/DVD-ROM Drive
1.
Observe the safety precautions, warnings, and cautions described in “
2.
Turn off all peripheral devices connected to the system.
3.
Power down the system and unplug both AC power cords.
4.
Remove the top cover. For instructions, see “Removing the Top Cover”, page 144.