Removing the Intel
®
Management Module
1.
Observe the safety precautions, warnings, and cautions described in “
2.
Turn off all peripheral devices connected to the system.
3.
Power down the system and unplug both AC power cords.
4.
Remove the top cover. For instructions, see “Removing the Top Cover”, page 144.
5.
Remove the memory boards or memory board air baffles from Slots A and B. For instructions,
see “
6.
Remove the Intel
®
Management Module. In removing the Module, be sure to hold the module
both by the loop finger grip and by the opposite corner, as shown by the two letters “A” in
Figure 114. Do not twist or bend the Module.
7.
Install memory boards or memory board air baffles into Slots A and B.
8.
Re-install the top cover.
TP01555
A
B
A
Figure 114. Removing the Intel
®
Management Module