56
Intel
®
Server System SR1530CL / SR1530HCL / SR1530HCLS
Removing a Slimline Optical Drive (SR1530CL)
1. Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see
“Removing the Server
System Cover” on page 28
.
4. Remove the front bezel if it is installed. For instructions, see
“Removing the Front
Bezel” on page 26
.
5. Note the orientation of the PCI cooling fan that is located behind the optical drive
bay, then lift the fan from the mounting pegs. It is not necessary to disconnect the
fan cable. See letter “A” in the following figure.
Figure 56. Lifting PCI Cooling Fan from Mounting Pegs (SR1530CL)
6. Disconnect the optical drive power and data cables. See letters “A” and “B” in the
following figure.
7. Remove the screw that holds the optical drive bracket to the server chassis. See
letter “C”. Save this screw. You will reinstall it later.
8. Slide the optical drive out through the front of the system. See letter “D”.
A
AF0009
88
Summary of Contents for SR1530CL - Server System - 0 MB RAM
Page 6: ...vi Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 16: ...xvi Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 18: ...xviii Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 22: ...xxii Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 46: ...24 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 124: ...102 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 140: ...118 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 152: ...130 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 176: ...154 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 188: ...166 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...