110
Intel
®
Server System SR1530CL / SR1530HCL / SR1530HCLS
•
Make sure the other adapter supports shared interrupts. Make sure your operating
system supports shared interrupts.
•
Try reseating the add-in adapter.
The add-in adapter stopped working without apparent cause
•
Reseat the adater.
•
Put the adapter in a different slot.
•
The network driver files may be corrupt or deleted. Delete and then reinstall the
drivers.
•
Run diagnostics.
System Boots when Installing PCI Card
System Management features require full-time "standby" power. This means some parts
of the system have power going to them whenever the power cord is plugged in, even if
you have turned the system power off with the power button on the front panel. If you
install a PCI card with the AC power cord plugged in, a signal may be sent to command
the system to boot. Before installing a PCI card, you should always:
•
Turn off the server power by using the power button on the front of the system.
•
Unplug the AC power cord(s) from the server.
Problems with Newly Installed Application Software
Problems that occur when you run new application software are usually related to the
software, not the server hardware. Faulty equipment is unlikely, especially if other
software runs correctly.
Check the following:
•
Make sure the system meets the minimum hardware requirements for the software.
See the software documentation.
•
Make sure the software is properly installed and configured for the system. See the
software documentation.
•
Use only an authorized copy. Unauthorized copies often do not work.
•
If you are running the software from a CD-ROM or DVD-ROM, try a different disk.
•
Make sure the correct device drivers installed.
If the problems persist, contact the software vendor's customer service representative.
Summary of Contents for SR1530CL - Server System - 0 MB RAM
Page 6: ...vi Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 16: ...xvi Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 18: ...xviii Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 22: ...xxii Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 46: ...24 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 124: ...102 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 140: ...118 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 152: ...130 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 176: ...154 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 188: ...166 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...