Forcing a BMC Update
1. Power down the system and disconnect the AC power.
2. Open the server.
3. Move the jumper from the Disabled position, covering pins 1 and 2 to the Enabled
position, covering pins 2 and 3.
Figure 15. BMC Force Update Jumper
4. Reconnect the AC power
5. Power up the system.
6. When the system begins beeping, power it down and disconnect the AC power.
7. Return the jumper to the Disabled location, covering pins 1 and 2.
8. Close the server chassis.
9. Reconnect the AC power and power up the system.
AF001279
Force Upd
a
te
J3A1
3
3
2-3: Enabled
1-2: Disabled
(Default)