Intel
®
Server System SR1530CL / SR1530HCL / SR1530HCLS
35
Figure 28. Installing the Memory
5. Make sure the clips at both ends of the DIMM socket(s) are pushed outward to the
open position. See letter “A” in
Figure 28
.
6. Holding the DIMM by the edges, remove it from its anti-static package.
7. Position the DIMM above the socket. Align the notch on the bottom edge of the
DIMM with the key in the DIMM socket. See letter “B” in the figure.
8. Insert the bottom edge of the DIMM into the socket. See letter “C” in the figure.
9. When the DIMM is correctly positioned, push down on the top edge of the DIMM
until the retaining clips snap into place.
10. Make sure the clips are firmly in place. See letter “D” in the figure.
11. Install the server system cover. For instructions, see
“Installing the Server System
Cover” on page 29
.
Removing DIMMs
To remove a DIMM, follow these steps:
1. Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
AF00064
8
DIMM A1
Socket
DIMM A2
Socket
DIMM A3
Socket
DIMM B3
Socket
DIMM B2
Socket
DIMM B1
Socket
A
C
D
B
Summary of Contents for SR1530CL - Server System - 0 MB RAM
Page 6: ...vi Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 16: ...xvi Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 18: ...xviii Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 22: ...xxii Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 46: ...24 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 124: ...102 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 140: ...118 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 152: ...130 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 176: ...154 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...
Page 188: ...166 Intel Server System SR1530CL SR1530HCL SR1530HCLS ...