Intel® Server System R2600SR Setup and Service Guide
61
3.15
Replacing the External I/O Module (EIOM)
Each compute node has two dedicated 10 GB ports routed to the 8-port Ethernet I/O Module (EIOM) at the
rear of the system. The ports are connected to the integrated Intel® Ethernet Connection X722 Controller.
3.15.1
Removing the System Shuttle
In order to remove the EIOM from the system, the system shuttle must be removed. Perform the following
steps to remove the system shuttle:
Figure 52. Removing the system shuttle
1.
Turn off all compute nodes and peripheral devices through the web console. Remove all power cords.
2.
Disengage all compute nodes from the system chassis by releasing and rotating the front handle in
each node (see Section 3.2.1).
3.
Disconnect the power cords and all external cables from the rear side of the system.
a.
If a cable management arm is installed, remove it.
4.
Turn the two thumbscrews securing the system shuttle counterclockwise and lift the handles up (see
Number 1).
5.
Pull the handles up and firmly slide the shuttle approximately halfway out until it stops (see
Number 2).
6.
Push up on the two release latches located on each side of the bottom of the shuttle and finish
removing the shuttle (see Number 3).