Intel® Server System R2600SR Setup and Service Guide
43
3.11
Updating the System Configuration after System Board Replacement
After a system board has been replaced, complete the steps in the sections below to update the system
configuration.
3.11.1
Updating the Universal Unique Identifier (UUID)
The Universal Unique Identifier (UUID) must be updated when the system board is replaced. Two methods
may be used to update the UUID.
3.11.1.1
BMC Provisioning Manager
Use the BMC Provisioning Manager to update the UUID for the system. Follow these steps:
1.
Start the system and press F1 to display the BMC Provisioning Manager System Setup interface.
2.
From the System Summary page, click Update VPD.
3.
Update the UUID.
3.11.1.2
OneCLI
OneCLI is an on-line tool that supports a number of different operating systems.
To download OneCLI, complete the following steps:
1.
Download and install OneCLI.
a.
http://downloadcenter.intel.com/
and navigate to the support page for the server.
b.
Click Drivers & Software.
c.
Navigate to the version of OneCLI for the operating system and download the package.
2.
Make sure that the correct version is downloaded for the operating system installed on the system.
3.
Follow the steps below to update UUID using OneCLI. OneCLI sets the UUID in the BMC Controller.
4.
Select one of the following methods to access the BMC Controller and set the UUID:
a.
Online from the target system, such as LAN or keyboard console style (KCS) access
b.
Remote access to the target system (LAN-based)
c.
Bootable medium containing ASU (LAN or KCS, depending upon the bootable media)
5.
Follow the steps below to set the UUID using One CLI.
a.
Copy and unpack the OneCLI package, which also includes other required files, to the solution.
b.
Make sure that to unpack the OneCLI and the required files to the same directory.
c.
After installing OneCLI, use the following command syntax to set the UUID:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
[access_method]
where:
<uuid_value>
Up to 16-byte hexadecimal value assigned by customer.
[access_method]
Select the access method from one of the following:
Online authenticated LAN access, type the command:
[−−imm imm_user_id:imm_password@imm_internal_ip]
where:
imm_internal_ip
The BMC (Lenovo XClarity Controller) internal LAN/USB IP address. The default value is
169.254.95.118.
imm_user_id
The BMC Controller account (1 of 12 accounts). The default value is USERID.
Summary of Contents for R2600SR Series
Page 2: ...Blank page...