Server System Features
8
Intel
®
Server System R1000EP Service Guide
System Recovery Jumpers
Jumper Name
Jumper Purpose
A
BIOS Default (J1L4)
If pins 2-3 are selected, the BIOS settings are cleared on the next
reset. These pins should be selected on 1-2 for normal system
operation.
B
BIOS Recover (J1L6)
If pins 2-3 are selected, the system can only boot from EFI-bootable
recovery media with the recovery BIOS image. The main system
BIOS will not boot. These pins should be selected on 1-2 for normal
system operation.
C
ME Force Update (J1L7)
If pins 2-3 are selected, the ME Force Update Mode is enabled.
These pins should be selected on 1-2 for normal system operation.
D
BMC Force Update (J2L4)
If pins 2-3 are selected, the Integrated BMC Force Update Mode is
enabled. These pins should be selected on 1-2 for normal system
operation.
E
Password Clear (J2L5)
If pins 2-3 are selected, administrator and user passwords are cleared
within five to ten seconds after the system is powered on. These pins
should be selected on 1-2 for normal system operation.
Figure 9. Configuration Jumpers