Appendix A: Technical Reference
52
Intel
®
Server System R1000EP Service Guide
Appendix A: Technical Reference
Power Supply Input Voltages
600W power supply module
100 - 127 V at 50/60 Hz 5.8 A
200 - 240 V at 50/60 Hz 2.9 A
Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each voltage. For
information about calculating the power usage for your configuration, please use the Power
Budget Tool.
Table 5. Power Supply Output Capability
Voltage
Maximum Current
12V
41.0A
5VSB
4.5A
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 6. System Environmental Limits Summary
Parameter
Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C/hour
Non-Operating Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing at 35°C
Acoustic noise
Sound power: 7.0 BA in an idle state at typical office ambient temperature. (23
+/- 2
°
C)
Shock, operating
Half sine, 2g peak, 11 milliseconds
Shock, unpackaged
Trapezoidal, 25g, velocity change 136 inches/second (
>=
40lbs to < 80lbs)
Shock, packaged
Non-palletized free fall in height 24
"
(
>=
40lbs to < 80lbs)
Vibration, unpackaged
5Hz to 500Hz, 2.20g RMS random
Summary of Contents for R1000EP series
Page 12: ......