Intel® Server System M70KLP Family Service Guide
68
Figure 87. Drive Assembly Installation to Front Drive Bay
5.
Ensure the drive carrier latch is in the outward open position.
6.
Carefully push the drive assembly into the drive bay until fully inserted.
7.
Close the drive carrier latch to secure the drive to the drive bay.
5.6
Intel® VROC 7.5 Key Replacement
This section provides instructions to replace an Intel® VROC for NVMe Key.
Required Tools and Supplies
•
Anti-static wrist strap and ESD safe workbench (recommended)
•
Replacement Intel® VROC 7.5 key
System Prerequisites
•
The system must be powered off and AC power cord(s) disconnected
5.6.1
Intel® VROC 7.5 (VMD NVMe* RAID) Key Removal
Figure 88. Intel® VROC Key Removal
1.
Locate the Intel® VROC for NVMe Key near the bottom right edge of the server board.
2.
Using the key pull tab, carefully pull up on the key until it disengages from the connector.