Technical Information
SCR
26
7.5
RS232 interface
Figure 6: SCR
–
RS232 interface connection
Connector Signal
Description
1
DCD
Data Carrier Detect
2
RXD
Receive Data
3
TXD
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Ground
6
DSR
Data Set Ready
7
RTS
Request To Send
8
CTS
Clear To Send
9
RI
Ring Indication
Table 1 0: SCR
–
RS232 interface connection
The RS232 interface conforms to the layout as DTE (Data Terminal
Equipment)
7.6
Connecting the connectors
The wires are contacted in the connector via screw terminals. The tightening
torque is 0.5
–
0.6 Nm.
The permissible wire cross-sections can be found in the following table.
Wire
Cross-section
Nominal cross-section
1.5 mm²
Rigid
0.2
–
1.5 mm²
Flexible
0.2
–
1.5 mm²
Flexible with end sleeve
0.25
–
1.5 mm²
Table 1 1: Permissible wire cross-sections for connectors
7.7
Maximum line lengths
The maximum line lengths to the connections can be found in the following table.
Wire
Max. length
Antennas, power supply, serial interfaces, inputs and outputs,
other signals
30 m
Table 1 2: Permissible line lengths