Technical Data
INSYS Modem 336 LL 2D/4D 5.x Originate / Answer
4
Technical Data
4.1
Physical Features
Danger!
Overvoltage.
Fire hazard!
The modem must be secured with a suitable fuse against
overvoltage.
All specified data was measured with a nominal input voltage, at full load, and an ambi-
ent temperature of 25 °C. The threshold value tolerances are subject to typical fluctua-
tions.
Physical Feature
Value
Operating voltage
minimum 10 V DC
maximum 60 V DC
Level alarm inputs
Level HIGH = 4-12V
Level LOW = 0-1V
Signal Level
Minimum -15dBm
Maximum -6 dBm
Input current from GND to in5V
Typically 0.5mA
Switch output, maximum switch voltage
30V (DC) / 42V (AC)
Switch output, maximum current load
1 A (DC) / 0.5 A (AC)
Power input sleep
2W
Power input connection
2.5W
Weight
250g
Dimensions (Width x Depth x Height)
55mm x 110mm x 75mm
Temperature range
0°C – 55°C
Maximum allowed humidity
95% non-condensing
Table 1: Physical Features