S Registers
INSYS Modem 336 LL 2D/4D 5.x Originate / Answer
S12*
Transmission clock of the ESC characters
Minimum pre and post run time and maximum interim time in 1/50 of seconds
between two characters. This must be observed, if the modem is supposed to de-
tect an abort sequence (u++).
S13*
Number of dialing attempts to send a message
Bit Meaning
Bit 0 – 3
Number of dialing attempts
Range of values: 1...12
Default value: 3
S13 determines the number of attempts to send the
message.
Note:
The limitation to a maximum of 12 at-
tempts is necessary for approval pur-
poses (black listing).
Bit 4 - 7
Reserved
S14*
General
settings
Bit Meaning
Bit 0
Reserved
Bit 1
Echo on inputs
Command echo
0: Echo off
1:
Echo
on
Bit 2
Reserved
Bit 3
Result format
Result codes:
0: Message numbers (
ATV0
)
1: Message texts (
ATV1
)
Bit 4
Reserved
Bit 5
Tone/pulse dialing
Tone/pulse
0: Tone dialing (
ATT
)
1: Pulse dialing (
ATP
)
Bit 6
Reserved
Bit 7
Originate/answer
Originate/answer 0:
Answer
mode
1: Originate mode
S15*
DTC Time Settings
The idle connection control is a function integrated in the firmware which moni-
tors the data transmission in online mode. This function prevents the modem to
stay online for an unlimited amount of time, although no data is being transmit-
ted anymore.
In the register S15, any time period between 1 and 255 seconds may be entered. If
S15 is set to 0, the idle connection control is switched off.
The timer will run immediately after the modem goes off-hook. As soon as the
timer has run out, a modem reset is performed (which will forcibly lead to the
hanging up of the modem).