Multi-Unlinking
Multi-Unlinking Mode can be used to quickly remove devices from an INSTEON scene. You may remove
as many of the Linked Responders from the scene as you would like.
The following will work for the most common INSTEON devices:
1) Set the Controller to Unlinking Mode. (For most Controllers, press & hold the desired On or Scene
button for 10 seconds
twice
or the Set button for 3 seconds
twice.
)
2) Tap
the
Set button on the Controller. If the Controller does not have a Set button, tap the same On or
Scene button you used to put the Controller into Unlinking Mode.
Multi-Unlinking Mode will automatically time out after 4 minutes of inactivity.
3) For each of the Responders you wish to Unlink:
•
If the Responder is a multi-scene device (e.g., KeypadLinc), tap the Scene button you wish to
Unlink
•
Press & hold the Responder’s Set button for 3 seconds
4) After you have Unlinked the desired Responders, tap the Controller’s Set button to exit Multi-
Unlinking Mode. If the Controller does not have a Set button, tap the same On or Scene button you
used to put the Controller into Unlinking Mode.
5) Test that you have removed the desired devices from the INSTEON scene by pressing the buttons
you just Unlinked from on the Controller
Enabling / Disabling the Beeper
This procedure will toggle the ControLinc beeper sound on and off. With the beeper turned off, ControLinc
will no longer beep during button presses. However, the beeper will still sound when ControLinc enters
and exits setup modes. By default, the beeper is
on.
1) Simultaneously press & hold the All On and Dim buttons until it beeps (3 seconds)
The ControLinc Status LED should begin blinking
2) Tap the Bright button
ControLinc should double-beep and its Status LED should turn on solid
The beeper is now disabled and will no longer beep upon button presses until re-enabled.
To
re-enable the beeper,
repeat steps 1 and 2.
Enabling / Disabling the Status LED
This procedure toggles the ControLinc Status LED on and off. With the Status LED turned off, the LED
will no longer flash during button presses. However, the Status LED will still function when ControLinc
enters and exits setup modes. By default, the Status LED is
on.
1) Simultaneously press & hold the All On and Dim buttons until it beeps (3 seconds)
The ControLinc Status LED should begin blinking
2) Tap the All Off button
ControLinc should double-beep and its Status LED should turn off
The Status LED is now disabled and will no longer flash or turn on solid until re-enabled.