ControLinc Owner’s Manual 

 

CREATING AN INSTEON SCENE 

INSTEON scenes let you activate dramatic lighting moods with the press of just one button. For example, 
you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others off, all with 
the tap of a button on a Controller. 

INSTEON scenes are very easy to set up – just Link more than one Responder to the same On/Off or 
Scene button on a Controller. Then, when you press any of the Linked buttons on the Controller, all of the 
INSTEON devices Linked in the scene will respond as a group. 

To set up an INSTEON scene, you can individually Link each device to a Controller. Or, save time and 
create multiple Links. See 

Multi-Linking and Multi-Unlinking. 

 

ADVANCED FEATURES  

Multi-Linking and Multi-Unlinking 

Multi-Linking 

Multi-Linking Mode allows you to Link multiple INSTEON devices to a single Controller, one after the 
other. Once in Multi-Linking Mode, you can Link any number of Responders without having to press & 
hold the Controller’s On button for 10 seconds for each Responder. Using Multi-Linking Mode is the 
fastest way to create an INSTEON scene. 

The following will work for the most common INSTEON devices: 

1)  For each of the Responders you wish to control, set the device to the state you wish to activate from 

the Controller  

  If the Responder is a dimmable device, set the On-Level and Ramp Rate 

  If the Responder is a multi-scene device (e.g., another Keypad), tap the desired Scene button 

to illuminate the LED. (If you wish the Responder’s scene to turn off, tap the Scene button 
again to turn the LED off, and then proceed to the next step.) 

2)  Set the Controller to Linking Mode. (For most Controllers, press & hold the desired On or Scene 

button for 10 seconds or the Set button for 3 seconds.)  

3)  Tap the Set button on the Controller. If the Controller does not have a Set button, tap the same On or 

Scene button you used to put the Controller into Linking Mode. 

Multi-Linking Mode will automatically time out after 4 minutes of inactivity.   

4)  One at a time, press & hold each of the Responder’s Set buttons for 3 seconds

 

  

5)  After you have Linked all the desired Responders, tap the Controller’s Set button to exit Multi-Linking 

Mode. If the Controller does not have a Set button, tap the same On or Scene button you used to put 
the Controller into Linking Mode. 

6)  Test that the INSTEON scene is working as expected by pressing the button you just Linked to on the 

Controller  

Page 8 of 15 

 

Summary of Contents for ControLinc 2430

Page 1: ...ControLinc INSTEON Tabletop Controller Model 2430...

Page 2: ...nking and Multi Unlinking 8 Enabling Disabling the Beeper 9 Enabling Disabling the Status LED 9 Restoring Power to ControLinc 10 Resetting an On Off Button Pair to its Factory Default Settings 10 Rese...

Page 3: ...on pair Customizable label Key ControLinc Features Bright Dim buttons All On All Off buttons Hinged stand Setup is easy Links to other INSTEON devices in minutes Controls up to five INSTEON scenes Sta...

Page 4: ...tiple Responders but it can only have one Controller Controller sends INSTEON commands to other devices Responder reacts to commands sent out by another INSTEON device An INSTEON device may act as a C...

Page 5: ...e set for Non dimming Responders should immediately go full off To brighten all dimmable Responders Linked to a particular button pair press hold the On button Dimmable Responders should brighten unle...

Page 6: ...ff button pair you used on ControLinc tap the Bright button Dimmable Responders should brighten one of 32 steps unless they are already fully bright To incrementally dim the dimmable Responders Linked...

Page 7: ...LED should begin blinking You will have 4 minutes to complete steps 3 and 4 before Linking Mode automatically times out 4 Press hold the Responder s Set button for 3 seconds ControLinc should beep an...

Page 8: ...e The following will work for the most common INSTEON devices 1 For each of the Responders you wish to control set the device to the state you wish to activate from the Controller If the Responder is...

Page 9: ...ices from the INSTEON scene by pressing the buttons you just Unlinked from on the Controller Enabling Disabling the Beeper This procedure will toggle the ControLinc beeper sound on and off With the be...

Page 10: ...ease the Off button The ControLinc Status LED should flash once 4 Test that the On Off button pair no longer controls any Responders by tapping the On and Off buttons Responders should no longer respo...

Page 11: ...troLinc should beep once and its Status LED should continue blinking 5 Select the X10 Unit Code that you want to use 1 through 16 For 1 through 14 press the button with that label For 15 press the All...

Page 12: ...mand If a Controller does not receive this confirmation it will automatically retransmit the command up to five times While using at least one dual band device is required when using an RF only device...

Page 13: ...ing or Unlinking Mode The On or Off button may not have been held down long enough Be sure to hold down the On button for at least 10 seconds to enter Linking Mode For Unlinking be sure to hold down t...

Page 14: ...e the Bright or Dim buttons Unplug ControLinc for at least 10 seconds and then reinstall ControLinc is locked up A surge or excessive noise on the power line might have glitched it If the above doesn...

Page 15: ...her oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a par...

Reviews: