background image

ControLinc Owner’s Manual 

 

Installing ControLinc 

Plug ControLinc into an unswitched wall receptacle 

The ControLinc Status LED should turn on solid  

USING CONTROLINC  

Using the ControLinc Buttons 

On/Off Button Pairs 

The On and Off buttons have a dual purpose. The buttons can be tapped to turn the Linked Responders 
on and off. If held down, the On button will brighten and the Off button will dim any dimmable Linked 
Responders.  

NOTE: Press & holding the buttons will not affect any non-dimming Responders. 

 

To turn on 

all Responders Linked to a particular button pair, tap the On button 

Dimmable Responders should go to whatever On-Level they were set for, at whatever Ramp 
Rate they were set up for 

Non-dimming Responders should immediately go full-on  

 

To turn off 

all Responders Linked to a particular button pair, tap the Off button 

Dimmable Responders should go full-off at whatever Ramp Rate they were set for  

Non-dimming Responders should immediately go full-off 

 

 

To brighten 

all dimmable Responders Linked to a particular button pair, press & hold the On 

button 

Dimmable Responders should brighten, unless they are already at full-bright 

 

When you release the button, the dimmable Responders should stop brightening. 

 

To dim 

all dimmable Responders Linked to a particular button pair, press & hold the Off button  

Dimmable Responders should dim, unless they are already off 

 

When you release the button, the dimmable Responders should stop dimming.  

All On/All Off Buttons 

The All On and All Off buttons will turn on or off 

all 

Responders Linked to ControLinc, no matter which 

On/Off button pair they are Linked to. 

 

To turn on 

all 

Responders

 

Linked to ControLinc, tap the All On button 

Dimmable Responders should go to whatever On-Level they were set for, at whatever Ramp 
Rate they were set up for 

Non-dimming Responders should immediately go full-on  

 

To turn off 

all 

Responders 

Linked to ControLinc, tap the All Off button  

All Responders should go full-off at whatever Ramp Rate they were set for  

Page 5 of 15 

 

Summary of Contents for ControLinc 2430

Page 1: ...ControLinc INSTEON Tabletop Controller Model 2430...

Page 2: ...nking and Multi Unlinking 8 Enabling Disabling the Beeper 9 Enabling Disabling the Status LED 9 Restoring Power to ControLinc 10 Resetting an On Off Button Pair to its Factory Default Settings 10 Rese...

Page 3: ...on pair Customizable label Key ControLinc Features Bright Dim buttons All On All Off buttons Hinged stand Setup is easy Links to other INSTEON devices in minutes Controls up to five INSTEON scenes Sta...

Page 4: ...tiple Responders but it can only have one Controller Controller sends INSTEON commands to other devices Responder reacts to commands sent out by another INSTEON device An INSTEON device may act as a C...

Page 5: ...e set for Non dimming Responders should immediately go full off To brighten all dimmable Responders Linked to a particular button pair press hold the On button Dimmable Responders should brighten unle...

Page 6: ...ff button pair you used on ControLinc tap the Bright button Dimmable Responders should brighten one of 32 steps unless they are already fully bright To incrementally dim the dimmable Responders Linked...

Page 7: ...LED should begin blinking You will have 4 minutes to complete steps 3 and 4 before Linking Mode automatically times out 4 Press hold the Responder s Set button for 3 seconds ControLinc should beep an...

Page 8: ...e The following will work for the most common INSTEON devices 1 For each of the Responders you wish to control set the device to the state you wish to activate from the Controller If the Responder is...

Page 9: ...ices from the INSTEON scene by pressing the buttons you just Unlinked from on the Controller Enabling Disabling the Beeper This procedure will toggle the ControLinc beeper sound on and off With the be...

Page 10: ...ease the Off button The ControLinc Status LED should flash once 4 Test that the On Off button pair no longer controls any Responders by tapping the On and Off buttons Responders should no longer respo...

Page 11: ...troLinc should beep once and its Status LED should continue blinking 5 Select the X10 Unit Code that you want to use 1 through 16 For 1 through 14 press the button with that label For 15 press the All...

Page 12: ...mand If a Controller does not receive this confirmation it will automatically retransmit the command up to five times While using at least one dual band device is required when using an RF only device...

Page 13: ...ing or Unlinking Mode The On or Off button may not have been held down long enough Be sure to hold down the On button for at least 10 seconds to enter Linking Mode For Unlinking be sure to hold down t...

Page 14: ...e the Bright or Dim buttons Unplug ControLinc for at least 10 seconds and then reinstall ControLinc is locked up A surge or excessive noise on the power line might have glitched it If the above doesn...

Page 15: ...her oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a par...