Factory Reset 

Factory  Reset clears all user  settings from Keypad  including INSTEON scenes,  on-levels,  ramp  rates, X10 
addresses, etc.  

1) 

With a small screwdriver or your fingernail, pull out Set button to create an air gap. 

2) 

Wait 10 seconds. 

3)  Push in Set button hold. Do not let go.

 

 

Keypad will begin to emit a long beep.

 

4)  When the beep stops, release the Set button.

 

Device’s embedded software will rewrite all settings to factory defaults. 

A couple of seconds will pass. 

Keypad will double-beep and its LEDs will return to normal brightness. 

The connected load will turn on and Keypad will return to ready mode. 

 

Adjust Local Settings 

Each of the Keypad buttons is considered a “scene button,” meaning you can use any of the buttons on Keypad to 
creat

INSTEON scenes

. Each button will control its own scene, only sending commands to devices linked 

specifically to that button. Dimmable responders may behave differently, depending on whether you tap, double-tap 
or press and hold a button to activate/deactivate a scene. Non-dimming responders will not respond to press-and-
hold brighten or dim commands; they will only turn full-on or full-off in response to taps and double-taps. 

 

When the LED of the button is on, the scene has been activated (turned on). 

 

When the LED of the button is off, the scene has been deactivated (turned off). 

Activating/Deactivating scenes with the Keypad buttons: 

 

Tap

 to activate  

Dimmable responders will turn on at their preset on-level at their programmed ramp rate. 

 

Non-dimming responders will immediately turn full-on.

  

 

Tap

 to deactivate  

Dimmable responders will turn full-off at their programmed ramp rate. 

 

Non-dimming responders will immediately turn full-off.

 

 

Double-Tap

 to activate  

Responders (both dimming and non-dimming) will immediately turn full-on.

  

 

Double-Tap

 to deactivate  

Responders (both dimming and non-dimming) will immediately turn full-off.

 

 

Press and hold

 to activate  

Summary of Contents for 2334-232

Page 1: ...Page 1 of 24 Rev 6 19 2013 10 26 AM Keypad Dimmer Owner s Manual 2334 222...

Page 2: ...e Multiple Scene Responders 10 Synchronized Scenes 11 Changing Button Modes Toggle Non Toggle Mode 12 Adjust LED Brightness 12 Turn Button Beep On or Off 13 X10 Setup 13 Add X10 Address to a Button 13...

Page 3: ...non volatile memory even through power failures Beeper for easy setup assistance can also function as a chime module Local programming lockout available via software 2 year warranty Before Installatio...

Page 4: ...mer installed For example 600 W load control becomes 400 W with another dimmer to the immediate right or left Use a triple gang box with a mechanical switch in the center to avoid de rating IMPORTANT...

Page 5: ...Traveler wire to the black wire on Keypad A with a wire nut 8 Cap the other Traveler wire with a wire nut 9 Cap A s red wire 10 Connect neutral to A s white wire 11 Connect Ground to A s bare copper...

Page 6: ...te wire 12 Connect Ground to the first Keypad s bare copper wire 13 On the other switch with 3 wires connected find the Load wire connects switch to lights commonly red and the only non traveler and c...

Page 7: ...8 to cross link all keypads so that they all control the load 23 Reinstall the trim plates Local Control LEDs Button LED Meaning ON On All on OFF On All off MAIN On Off On All on MAIN On Off Off All...

Page 8: ...rammed INSTEON scenes let you activate dramatic lighting moods at the touch of a button For example you can set all the lights in a scene to dim to 50 or turn certain lights on while turning others of...

Page 9: ...apping the scene button on and off The responder will not respond 6 If you wish to remove multiple responders from Keypad repeat steps 1 5 for each additional responder or see Remove Multiple Responde...

Page 10: ...nder you are adding Adjust the responder to the desired scene state for Keypads you must tap the button at least once to reach the desired state Press and hold responder s Set button until it beeps an...

Page 11: ...controller button and Set button LED will flash A will double beep and its LEDs will stop blinking 4 Press and hold Switch B s Set button until it beeps B s scene controller LED will blink and Set but...

Page 12: ...utton it beeps again The button LEDs will continue blinking and Set button LED will blink red 4 Press and hold Keypad s Set button until it beeps a third time The button LEDs will stop blinking The bu...

Page 13: ...ou are no longer going to utilize an X10 address associated with Keypad it is very important that you remove its X10 address Otherwise Keypad will still listen for X10 commands somewhat hindering INST...

Page 14: ...ces linked specifically to that button Dimmable responders may behave differently depending on whether you tap double tap or press and hold a button to activate deactivate a scene Non dimming responde...

Page 15: ...d to Keypad will turn on The default local on level is 100 but can be set to any one of 33 settings 32 fixed brightness levels 3 to 100 or Resume Bright which will result in the light returning to the...

Page 16: ...is attached See Configuring for 6 or 8 Button Operation Changing Buttons Keypad buttons can be swapped out with custom etched buttons to customize its appearance Using a small flat edged screwdriver o...

Page 17: ...ly changed the Local On Level instead of the Local Ramp Rate note software allows you to set the on levels and ramp rates exactly as desired and consistently around the house Additional Resources Find...

Page 18: ...mer 8 Button Gray 2334 232 813922013177 Keypad Dimmer 6 Button White 2334 233 813922013184 Keypad Dimmer 6 Button Ivory 2334 234 813922013191 Keypad Dimmer 6 Button Almond 2334 235 813922013207 Keypad...

Page 19: ...White Neutral Red Load Bare Copper Ground Case Color Clear Set button 1 Plastic UV Stabilized Polycarbonate Beeper Yes LED 1 dual color greed red Unit Dimensions 4 1 H x 1 8 W x 1 4 D Box Dimensions 4...

Page 20: ...n unlinked INSTEON devices that had been previously linked to Keypad Dimmer Dual Band will still respond to button presses even after a factory reset The reason is that the INSTEON devices themselves...

Page 21: ...All INSTEON devices act as INSTEON network repeaters Make sure you are not experiencing interference with older X10 BoosterLinc technology Upgrade to INSTEON compatible BoosterLinc modules 4827 Keypad...

Page 22: ...tch to a non dimming Keypad On Off relay Switch Keypad does not respond at all A surge or excessive noise on the power line may have caused the Keypad to unexpectedly stop responding Pull the Set butt...

Page 23: ...ch can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or relocate the receiving antenna of the dev...

Page 24: ...ling your home In no event shall Seller be liable for special incidental consequential or other damages resulting from possession or use of this device including without limitation damage to property...

Reviews: