26
Step 3: Install the assembled heatsink module onto the CPU socket, and the position marked
by “1” should be aligned with the triangle mark on the CPU socket. Tighten the screws
according to the sequence of 1, 2, 3, 4.
Notes:
● It is required to coat thermal grease evenly onto the contact position between CPU
heatsink and CPU.
● During fixing CPU heatsink, it is required to fasten screws according to the sequence
accordingly.
6.3 Memory Option
●
DIMM population guidelines:
a.
Equal distribution: The DIMMs are evenly distributed to each CPU. When there is
a remainder, the remaining are assigned to CPU0-7 in turn.
b.
Installation position: For each CPU, the DIMM population follows the screen printed
sequence: C0D0, C3D0, C1D0, C4D0, C2D0, C5D0, C0D1, C3D1, C1D1, C4D1, C2D1, C5D1.
1.
Power down the server.
2.
Extend the compute node from the rack.
3.
Remove the top cover of the node.
4.
Remove the air baffle.