153
BMC Settings
8.16 Protocol and Ports
BMC supports network connection manager library to configure networking services
configuration in run-time. RCMP+, HTTP/HTTPS, KVM, CD-MEDIA, FD-MEDIA, HD-MEDIA,
SSH, TELNET and SOLSSH services are supported so far. Users can enable or disable theses
services, configure communication port, session timeout value of the service and the
maximum number of allowed sessions for the services.
Table 8-34 Protocols and Ports
Service
Usage
Default
State
Non-Security
Port
Security
Port
Default Port Timeout(s) Max
Session
RMCP+
IPMI
Enable
623
N/A
N/A
1800
20
HTTP/HTTPS Web GUI
Enable
80(Http)
443(Https) 443(Https)
1800
20
KVM
Console
Redirection
Enable
7578
7582
7578
1800
4
cd-media
Virtual Media Enable
5120
5124
5120
N/A
4
fd-media
Virtual Media Enable
5122
5126
5122
N/A
4
hd-media
Virtual Media Enable
5123
5127
5123
N/A
4
Ssh
ssh
Disable
N/A
22
22
600
N/A
telnet
telnet
Disable
23
N/A
23
600
N/A
solssh
sol by ssh
Enable
52123
N/A
N/A
60
N/A
Note1:
Http/Https (WEB) Timeout, if there is no web request in Timeout, web session will be
deleted, and new web request will not respond. If the web page has no auto update, it will
be logged out when you switch pages or refresh the page after timeout.
Note2:
Telnet is a non-security protocol, if not used, we suggest you disable it.
Fixed protocols can not be configured.
Table 8-35 Fixed Protocols
Service
Usage
State
Port
SNMP
SNMP Get/Set
Enable
161
syslog
syslog
Enable
514
Websockify
KVM on HTML5
Enable
9666
Websockify
Virtual Media on HTML5
Enable
9999
srvloc
Sever location
Enable
427
smux
Enable
199
Summary of Contents for NF8260M5
Page 1: ...Inspur Server User Manual NF8260M5 ...
Page 35: ...29 Hardware Options Installation Figure 6 4 DIMM population guidelines Figure 6 5 ...
Page 59: ...53 BIOS Setup Figure 7 33 Figure 7 34 ...
Page 98: ...92 Figure 7 74 Figure 7 75 ...
Page 126: ...120 chassis Figure 8 8 Chassis user Figure 8 9 User mc Figure 8 10 MC ...
Page 127: ...121 BMC Settings fan Figure 8 11 Fan psu Figure 8 12 Psu id Figure 8 13 Id diagnose ...
Page 178: ...172 Figure 8 58 SOL Setting in BIOS Figure 8 59 Default Serial Setting ...