Table 7-12 Console Redirection Settings Interface Instruction Table
Interface Parameters
Function Description
Default Value
Terminal Type
Terminal type settings. Options include:
VT100
VT100+
VT-UTF8
ANSI
ANSI
Bits per second
Baud rate settings. Options include:
9600
19200
38400
57600
115200
115200
Data Bits
Serial port data width settings. Options include:
7
8
8
Parity
Parity settings. Options include:
None
Even
Odd
Mark (odd-even check)
Space (storage parity check)
None
Stop Bits
Stop bit settings. Options include:
1
2
1
Flow Control
Flow control settings. Options include:
None
Hardware RTS/CTS
None
VT-UTF8 Combo Key Support
VT-UTF8 combination key support on-off settings.
Options include:
Enabled
Disabled
Enabled
Recorder Mode
Recorder mode on-off settings. Options include:
Enabled
Disabled
Disabled
Redirection 100×31
Expanded redirection resolution 100×31 on-off
settings. Options include:
Enabled
Disabled
Disabled
Legacy OS Redirection Resolution
Legacy OS redirection resolution settings. Options
include:
80×24
80×25
80×24
Putty KeyPad
Putty function keys and keyboard settings. Options
include:
VT100
LINUX
XTERMR6
SCO
ESCN
VT400
VT100
Redirection After BIOS POST
Redirection after BIOS POST settings. Options
include:
Always Enable
BootLoader
Always Enable
Summary of Contents for NF8260M5
Page 1: ...Inspur Server User Manual NF8260M5 ...
Page 35: ...29 Hardware Options Installation Figure 6 4 DIMM population guidelines Figure 6 5 ...
Page 59: ...53 BIOS Setup Figure 7 33 Figure 7 34 ...
Page 98: ...92 Figure 7 74 Figure 7 75 ...
Page 126: ...120 chassis Figure 8 8 Chassis user Figure 8 9 User mc Figure 8 10 MC ...
Page 127: ...121 BMC Settings fan Figure 8 11 Fan psu Figure 8 12 Psu id Figure 8 13 Id diagnose ...
Page 178: ...172 Figure 8 58 SOL Setting in BIOS Figure 8 59 Default Serial Setting ...