73
BIOS Setup
Figure 7-56
Table 7-25 Processor Configuration Interface Instruction Table
Interface Parameters
Function Description
Default Value
Processor Information
Processor information submenu, the processor’s detailed
information
----
Active Cores
CPU core settings. Input the number of CPU cores you
want to enable. In the Help information, it will display the
effective values you can set and the maximum number of
physical cores according to the current CPU usage.
The default value is 0, all cores enabled.
0
Intel(R) Hyper Threading Tech
Hyper threading technology on-off settings. Options
include:
Enabled
Disabled
Enabled
Max CPUID Value Limit
The max CPUID value limit on-off settings.
Enabled
Disabled
When the legacy OS boot does not support CPUID
function, please enable this option.
Disabled
Execute Disable Bit
Execute disable bit on-off setting. Options include:
Enabled
Disabled
Enabled
Intel(R) TXT
Intel trusted execution technology on-off settings. Options
include:
Enabled
Disabled
Disabled