BMC Settings
Intel ME firmware is packaged with BIOS firmware as a single firmware image.
Support two upgrade modes: “BIOS+ME” and “BIOS Only”.
Power off the system before performing BIOS firmware update.
After BIOS firmware update, BIOS NVRAM will be cleared, all BIOS configurations will be
reset to defaults.
If we update both BIOS and ME images, in order to make ME firmware take effort, it is
suggested to start the server after AC power off.
Step 1
Login Management Web GUI, enter “Administrator -> BIOS Firmware Update”, as shown
below. Select BIOS+ME or BIOS only, BIOS+ME by default. If you want to preserve BIOS
setup options, users need select “BIOS Setup Options”. PHY MAC is selected to be preserved
by default. Click “Enter Firmware Update Mode” button to enter update mode.
Figure 8-5
5
BIOS Update Step 1
Step 2
Select image file, and click Upload button to upload file. ME will enter recovery mode, and
then BMC will verify the image. Verify:
Size should be 32M.
Verify image integrity, it will make sure this is BIOS image.
If the verification fails, BMC will stop flash and change ME to normal mode.
If the verification succeeds, click “Proceed to Update” button to start update. Wait for about
3mins, then the flash is complete, and ME will enter the normal mode.
Summary of Contents for NF8260M5
Page 1: ...Inspur Server User Manual NF8260M5 ...
Page 35: ...29 Hardware Options Installation Figure 6 4 DIMM population guidelines Figure 6 5 ...
Page 59: ...53 BIOS Setup Figure 7 33 Figure 7 34 ...
Page 98: ...92 Figure 7 74 Figure 7 75 ...
Page 126: ...120 chassis Figure 8 8 Chassis user Figure 8 9 User mc Figure 8 10 MC ...
Page 127: ...121 BMC Settings fan Figure 8 11 Fan psu Figure 8 12 Psu id Figure 8 13 Id diagnose ...
Page 178: ...172 Figure 8 58 SOL Setting in BIOS Figure 8 59 Default Serial Setting ...