8.11.3 BMC Watchdog for System
Software watchdog can be used for a number of system timeout function by system
management or by BIOS. If software watchdog is triggered, the following actions are
available.
System Reset
System Power Off
System Power Cycle
When BMC watchdog working, BMC will record SEL log.
8.11.4 BMC Recovery
Users can reset BMC from WEB or IPMI interface in case of abnormal situation.
Warm reset BMC, use “ipmitool mc reset warm”, IPMI Server, KVM Server, WEB Server
will be reset.
Cold reset BMC, use WEB or “ipmtool mc reset cold”, BMC will be reset.
KVM reset, user WEB and KVM server will be reset.
Figure 8-35 BMC Recovery
8.12 BMC Self Recovery
BMC Self Recovery provides the ability of automatic repair operations as well if necessary.
8.12.1 Hardware Watchdog
Known fault scenarios:
Kernel panic
System resources exhausted or error, system can’t create a new task, but the original task
can continue to run.
Hardware watchdog:
Watchdog starts when uboot loads kernel, and the timeout is 5 minutes. If BMC boot
timeout occurs, BMC will reset.
After the BMC system starts, the main process resets the Watchdog every minute. If the
Summary of Contents for NF8260M5
Page 1: ...Inspur Server User Manual NF8260M5 ...
Page 35: ...29 Hardware Options Installation Figure 6 4 DIMM population guidelines Figure 6 5 ...
Page 59: ...53 BIOS Setup Figure 7 33 Figure 7 34 ...
Page 98: ...92 Figure 7 74 Figure 7 75 ...
Page 126: ...120 chassis Figure 8 8 Chassis user Figure 8 9 User mc Figure 8 10 MC ...
Page 127: ...121 BMC Settings fan Figure 8 11 Fan psu Figure 8 12 Psu id Figure 8 13 Id diagnose ...
Page 178: ...172 Figure 8 58 SOL Setting in BIOS Figure 8 59 Default Serial Setting ...