118
objects. It is an Internet Standard protocol for collecting and organizing information about
managed devices on IP networks and for modifying that information to change device
behavior.
In the BMC, the agent can obtain the server information such as network information, user
information, temperature/voltage/fan speed and so on through the SNMP service. At the
same time we can configure parameters and manage the server through BMC.
Support SNMP Get/Set/Trap.
Support V1/V2C/V3 version.
SNMPv3 supports authentication algorithm MD5 or SHA, and encryption algorithm to
DES or AES.
SNMP Get supports querying system health status, sensor status, hardware status, device
asset information, etc.
SNMP Set supports local users or network users to switch machine and other operations.
SNMP Trap supports IPM-based Trap messages.
SOL
Fault
Detect
BMC
snmptrapd
snmp
trap
snmp
get
snmpd
snmp
set
Figure 8-3 SNMP Schematic
8.6 Smash-Lite CLI
BMC supports Smash-Lite CLI, users can login to BMC via SSH and enter Smash-Lite CLI. And
it supports ipconfig, sensor, fru, chassis, user, mc, fan, psu, id, diagnose commands, as the
figure shows.
Smash-Lite help:
Summary of Contents for NF8260M5
Page 1: ...Inspur Server User Manual NF8260M5 ...
Page 35: ...29 Hardware Options Installation Figure 6 4 DIMM population guidelines Figure 6 5 ...
Page 59: ...53 BIOS Setup Figure 7 33 Figure 7 34 ...
Page 98: ...92 Figure 7 74 Figure 7 75 ...
Page 126: ...120 chassis Figure 8 8 Chassis user Figure 8 9 User mc Figure 8 10 MC ...
Page 127: ...121 BMC Settings fan Figure 8 11 Fan psu Figure 8 12 Psu id Figure 8 13 Id diagnose ...
Page 178: ...172 Figure 8 58 SOL Setting in BIOS Figure 8 59 Default Serial Setting ...