14
4.Reception and Installation
ED. 2010/11
4.7.4.
AS-i card with up to 2 solenoid valves and 2 detectors:
By default, the assembly is as follows:
1
AS-i +
2
AS-i -
3 n.c.
4 n.c.
5 +
6 0V
7
Outlet 2
Solenoid 2
8
Inlet 2
Switch 2
9 0V
10
Outlet 1
Solenoid 1
11
Inlet 1
Switch 1
This card is standard for the following heads:
DESCRIPTION CODE
C-TOP DETECTORES 24V DC 0E 2D AS-I
V9721-0284001AS
C-TOP DETECTORES 24V DC 1E 1D AS-I
V9721-1184001AS
C-TOP DETECTORES 24V DC 1E 2D AS-I
V9721-1284001AS
C-TOP DETECTORES 24V DC 2E 2D AS-I
V9721-2284001AS
4.8.
PNEUMATIC CONNECTIONS
Solenoid
Manual Switching
Solenoid Valves
1-2-3
General Air Inlet
General Air Outlet
Valve Outlet
(Mix Proof)
Valve Outlet
(Double Acting)
Valve Outlet
(Single Acting)
All the air connections are of the rapid type, for ø6 mm piping.