10
4.Reception and Installation
ED. 2010/11
4.5.2.
Wiring the head
4
Fit the electric
wiring, in the basic
version and connect
the
C
-
TOP
electrically. (See
electrical
connections 4.6
)
Check to make
sure that the wire
guide is good and
tight.
5
Connect the ø6
mm. pipes for the
air to the
C
-
TOP
(See
pneumatic
connections 4.7
).
4.5.3.
Adjusting the position detectors
In order to place the detectors at the operating position (or detection position, the regulating screw for each detector must be
tightened:
•
screw clockwise to raise the detector.
•
screw anti-clockwise to lower the detector.
6
Adjust the height
of the position
indicators with a
screwdriver.
7
Make sure all of
the connections
(both the air
and electrical
connections)
are properly
coupled, cover
the
C
-
TOP
,
making sure to
position the
seal correctly,
then tighten the
three screws
appropriately.
This operation must always be carried out with the head connected to the mains, given that as soon as the detection position
has been reached, the status LED indicator will come on. Carry out the adjustment operation for each one of the head position
indicators.
After doing maintenance work on the heads, ALWAYS put the cover back in order to protect the
internal electrical components.